A closer look at high-energy X-ray-induced bubble formation during soft tissue imaging

crossmark logo

aDepartment of Mechanical Engineering, University College London, London, United Kingdom, bEuropean Synchrotron Radiation Facility, Grenoble, France, cSchool of Engineering, Lancaster University, Bailrigg, Lancaster LA1 4YW, UK, dDepartment of Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg, Germany, and eTranslational Lung Research Centre Heidelberg (TLRC), German Lung Research Centre (DZL), Heidelberg, Germany
*Correspondence e-mail: xrpatrick@gmail.com, j.brunet@ucl.ac.uk, peter.lee@ucl.ac.uk, paul.tafforeau@esrf.fr

Edited by R. Ingle, University College London, United Kingdom (Received 24 January 2024; accepted 2 April 2024; online 26 April 2024)

Improving the scalability of tissue imaging throughput with bright, coherent X-rays requires identifying and mitigating artifacts resulting from the interactions between X-rays and matter. At synchrotron sources, long-term imaging of soft tissues in solution can result in gas bubble formation or cavitation, which dramatically compromises image quality and integrity of the samples. By combining in-line phase-contrast imaging with gas chromatography in real time, we were able to track the onset and evolution of high-energy X-ray-induced gas bubbles in ethanol-embedded soft tissue samples for tens of minutes (two to three times the typical scan times). We demonstrate quantitatively that vacuum degassing of the sample during preparation can significantly delay bubble formation, offering up to a twofold improvement in dose tolerance, depending on the tissue type. However, once nucleated, bubble growth is faster in degassed than undegassed samples, indicating their distinct metastable states at bubble onset. Gas chromatography analysis shows increased solvent vaporization concurrent with bubble formation, yet the quantities of dissolved gasses remain unchanged. By coupling features extracted from the radiographs with computational analysis of bubble characteristics, we uncover dose-controlled kinetics and nucleation site-specific growth. These hallmark signatures provide quantitative constraints on the driving mechanisms of bubble formation and growth. Overall, the observations highlight bubble formation as a critical yet often overlooked hurdle in upscaling X-ray imaging for biological tissues and soft materials and we offer an empirical foundation for their understanding and imaging protocol optimization. More importantly, our approaches establish a top-down scheme to decipher the complex, multiscale radiation–matter interactions in these applications.

1. Introduction

X-ray imaging and spectroscopic techniques are being gradually adopted and refined for probing biological systems with unprecedented resolution and sensitivity (Hémonnot & Köster, 2017[Hémonnot, C. Y. J. & Köster, S. (2017). ACS Nano, 11, 8542-8559.]; Sanchez-Cano et al., 2021[Sanchez-Cano, C., Alvarez-Puebla, R. A., Abendroth, J. M., Beck, T., Blick, R., Cao, Y., Caruso, F., Chakraborty, I., Chapman, H. N., Chen, C., Cohen, B. E., Conceição, A. L. C., Cormode, D. P., Cui, D. et al. (2021). ACS Nano, 15, 3754-3807.]). Soft biological samples are prone to radiation damage (Howells et al., 2009[Howells, M. R., Beetz, T., Chapman, H. N., Cui, C., Holton, J. M., Jacobsen, C. J., Kirz, J., Lima, E., Marchesini, S., Miao, H., Sayre, D., Shapiro, D. A., Spence, J. C. H. & Starodub, D. (2009). J. Electron Spectrosc. Relat. Phenom. 170, 4-12.]; Rez, 2021[Rez, P. (2021). Ultramicroscopy, 231, 113301.]) in their natural conditions or the preferred condition to study, which requires procedural adjustment of existing X-ray techniques which are more attuned to studying crystalline samples or small samples of (radiation) hard materials. For X-ray imaging, wet embedding in liquid solvents or gels is inherently an efficient and scalable preparation method because it can accommodate deformable samples of arbitrary sizes, from thin or thick slices (Disney et al., 2022[Disney, C. M., Mo, J., Eckersley, A., Bodey, A. J., Hoyland, J. A., Sherratt, M. J., Pitsillides, A. A., Lee, P. D. & Bay, B. K. (2022). Acta Biomater. 138, 361-374.]) to entire organs (Walsh et al., 2021[Walsh, C. L., Tafforeau, P., Wagner, W. L., Jafree, D. J., Bellier, A., Werlein, C., Kühnel, M. P., Boller, E., Walker-Samuel, S., Robertus, J. L., Long, D. A., Jacob, J., Marussi, S., Brown, E., Holroyd, N., Jonigk, D. D., Ackermann, M. & Lee, P. D. (2021). Nat. Methods, 18, 1532-1541.]) and whole organisms (Socha et al., 2007[Socha, J. J., Westneat, M. W., Harrison, J. F., Waters, J. S. & Lee, W. (2007). BMC Biol. 5, 6.]; Moosmann et al., 2013[Moosmann, J., Ershov, A., Altapova, V., Baumbach, T., Prasad, M. S., LaBonne, C., Xiao, X., Kashef, J. & Hofmann, R. (2013). Nature, 497, 374-377.]; Kitchen et al., 2017[Kitchen, M. J., Buckley, G. A., Gureyev, T. E., Wallace, M. J., Andres-Thio, N., Uesugi, K., Yagi, N. & Hooper, S. B. (2017). Sci. Rep. 7, 15953.]). Wet embedding compares favorably with other sample immobilization techniques, such as the use of solid paraffin or resin (Zhanmu et al., 2020[Zhanmu, O., Yang, X., Gong, H. & Li, X. (2020). Sci. Rep. 10, 12639.]), which can be time-consuming for impregnating thick tissues, or high-pressure freezing (Jacobsen, 2020[Jacobsen, C. (2020). X-ray Microscopy, pp. 457-495. Cambridge University Press.]), which is currently limited to submillimeter-thin samples. In imaging wet biological samples embedded in solution or gel, the formation of gas bubbles and their dynamical evolution are important issues that compromise the outcome (Saccomano et al., 2018[Saccomano, M., Albers, J., Tromba, G., Dobrivojević Radmilović, M., Gajović, S., Alves, F. & Dullin, C. (2018). J. Synchrotron Rad. 25, 1153-1161.]; Mittone et al., 2020[Mittone, A., Fardin, L., Di Lillo, F., Fratini, M., Requardt, H., Mauro, A., Homs-Regojo, R. A., Douissard, P.-A., Barbone, G. E., Stroebel, J., Romano, M., Massimi, L., Begani-Provinciali, G., Palermo, F., Bayat, S., Cedola, A., Coan, P. & Bravin, A. (2020). J. Synchrotron Rad. 27, 1347-1357.]), but to date lack quantitative study. Bubbles in this context are closed gas–liquid interfaces exhibiting a high refractive index gradient across the boundary (Lee et al., 2013[Lee, J. S., Weon, B. M. & Je, J. H. (2013). J. Phys. D Appl. Phys. 46, 494006.]). For X-ray phase contrast, often adopted for imaging soft tissues (Walsh et al., 2021[Walsh, C. L., Tafforeau, P., Wagner, W. L., Jafree, D. J., Bellier, A., Werlein, C., Kühnel, M. P., Boller, E., Walker-Samuel, S., Robertus, J. L., Long, D. A., Jacob, J., Marussi, S., Brown, E., Holroyd, N., Jonigk, D. D., Ackermann, M. & Lee, P. D. (2021). Nat. Methods, 18, 1532-1541.]; Bravin et al., 2013[Bravin, A., Coan, P. & Suortti, P. (2013). Phys. Med. Biol. 58, R1-R35.]; Busse et al., 2018[Busse, M., Müller, M., Kimm, M. A., Ferstl, S., Allner, S., Achterhold, K., Herzen, J. & Pfeiffer, F. (2018). Proc. Natl Acad. Sci. USA, 115, 2293-2298.]; Töpperweien et al., 2018[Töpperwien, M., van der Meer, F., Stadelmann, C. & Salditt, T. (2018). Proc. Natl Acad. Sci. USA, 115, 6940-6945.]), the strong edge-enhancing effect from gas bubbles (Wilkins et al., 1996[Wilkins, S. W., Gureyev, T. E., Gao, D., Pogany, A. & Stevenson, A. W. (1996). Nature, 384, 335-338.]; Tsai et al., 2002[Tsai, W. L., Hsu, P. C., Hwu, Y., Chen, C. H., Chang, L. W., Je, J. H., Lin, H. M., Groso, A. & Margaritondo, G. (2002). Nature, 417, 139.]) largely eclipses the inherent phase contrast from (unstained) soft tissues (Wen et al., 2013[Wen, H., Gomella, A. A., Patel, A., Lynch, S. K., Morgan, N. Y., Anderson, S. A., Bennett, E. E., Xiao, X., Liu, C. & Wolfe, D. E. (2013). Nat. Commun. 4, 2659.]). Although exogenous micrometre-sized bubbles (microbubbles) may be injected into the sample to enhance contrast (Lång et al., 2019[Lång, K., Arboleda, C., Forte, S., Wang, Z., Prevrhal, S., Koehler, T., Kuhn, N., David, B., Jefimovs, K., Kubik-Huch, R. A. & Stampanoni, M. (2019). Eur. Radiol. Exp. 3, 19.]; Tang et al., 2021[Tang, R., Li, Y., Qin, L., Yan, F., Yang, G. & Chen, K. (2021). Med. Phys. 48, 3459-3469.]), their uncontrolled creation during X-ray irradiation (Bras et al., 2021[Bras, W., Myles, D. A. A. & Felici, R. (2021). J. Phys. Condens. Matter, 33, 423002.]) is detrimental to long scans required for high-resolution imaging of large samples (Walsh et al., 2021[Walsh, C. L., Tafforeau, P., Wagner, W. L., Jafree, D. J., Bellier, A., Werlein, C., Kühnel, M. P., Boller, E., Walker-Samuel, S., Robertus, J. L., Long, D. A., Jacob, J., Marussi, S., Brown, E., Holroyd, N., Jonigk, D. D., Ackermann, M. & Lee, P. D. (2021). Nat. Methods, 18, 1532-1541.]) or for in vivo dynamic monitoring in developmental biology (Moosmann et al., 2013[Moosmann, J., Ershov, A., Altapova, V., Baumbach, T., Prasad, M. S., LaBonne, C., Xiao, X., Kashef, J. & Hofmann, R. (2013). Nature, 497, 374-377.]), physiology (Leong et al., 2014[Leong, A. F. T., Buckley, G. A., Paganin, D. M., Hooper, S. B., Wallace, M. J. & Kitchen, M. J. (2014). Biomed. Opt. Expr. 5, 4024.]) and beyond. Due to bubble growth and their motion, the experiments need to be interrupted and the sample reprocessed to mitigate the strong imaging artifacts (Xian et al., 2022[Xian, R. P., Walsh, C. L., Verleden, S. E., Wagner, W. L., Bellier, A., Marussi, S., Ackermann, M., Jonigk, D. D., Jacob, J., Lee, P. D. & Tafforeau, P. (2022). Sci. Data, 9, 264.]) [see Figs. 1[link](a)–1(c)]. The cavitation process and the subsequent bubble motion can potentially also cause damage (Barney et al., 2020[Barney, C. W., Dougan, C. E., McLeod, K. R., Kazemi-Moridani, A., Zheng, Y., Ye, Z., Tiwari, S., Sacligil, I., Riggleman, R. A., Cai, S., Lee, J., Peyton, S. R., Tew, G. N. & Crosby, A. J. (2020). Proc. Natl Acad. Sci. USA, 117, 9157-9165.]; Hasan et al., 2021[Hasan, F., Al Mahmud, K. A. H., Khan, M. I., Patil, S., Dennis, B. H. & Adnan, A. (2021). Multiscale Sci. Eng. 3, 67-87.]) to fragile tissue microstructures, like in brains or embryos (Moosmann et al., 2013[Moosmann, J., Ershov, A., Altapova, V., Baumbach, T., Prasad, M. S., LaBonne, C., Xiao, X., Kashef, J. & Hofmann, R. (2013). Nature, 497, 374-377.]), especially in high-resolution bio­imaging settings that are increasingly being adopted for elucidating multiscale information and spatiotemporal processes. Therefore, identification of the experimental conditions and underlying mechanisms that induce bubble formation in high-energy X-ray imaging is crucial.

[Figure 1]
Figure 1
Experimental investigation of X-ray-induced gas bubble formation. (a) Bubble formation during X-ray phase-contrast tomography of human liver tissue during a beamline incident, when a high-energy X-ray beam was in the same location (about 4 h instead of the normal scanning time of 10 min) due to scanning software malfunction. The bubbles create huge streaking artifacts in the reconstructed image. (b) For comparison, the imaging outcome of the same sample without bubbles after re-degassing following the incident. The liver images are only shown here to illustrate the deleterious effects of bubbles in synchrotron X-ray experiments. Image modified from Brunet et al. (2023[Brunet, J., Walsh, C. L., Wagner, W. L., Bellier, A., Werlein, C., Marussi, S., Jonigk, D. D., Verleden, S. E., Ackermann, M., Lee, P. D. & Tafforeau, P. (2023). Nat. Protoc. 18, 1441-1461.]). (c) Bubbles revealed (black arrows) by differential intensities between (a) and (b) within the region specified in (a). The contrast change, such as the negative differential signal within the liver vasculature, is primarily caused by bubble formation. (d) Experimental setup for probing the phenomenon using a micro-gas chromatograph for online detection. A small hole was drilled in the sealed red lid of the sample container to let the gas escape. (e) Photograph of the sample container in a sealed external housing.

So far, the conditions and consequences of radiation-induced bubble formation have mostly been investigated in the context of spectroscopy (Mesu et al., 2006[Mesu, J. G., Beale, A. M., de Groot, F. M. F. & Weckhuysen, B. M. (2006). J. Phys. Chem. B, 110, 17671-17677.]) and crystallography (Meents et al., 2010[Meents, A., Gutmann, S., Wagner, A. & Schulze-Briese, C. (2010). Proc. Natl Acad. Sci. USA, 107, 1094-1099.]) at low X-ray energies (<15 keV), where a focused beam geometry in the application contexts greatly intensifies the interaction between X-rays and matter. Moreover, in that energy regime, photochemical processes typically dominate due to the strong X-ray photoelectric effects. For hard X-rays (≥10 keV) (Reichert & Honkimäki, 2015[Reichert, H. & Honkimäki, V. (2015). In Synchrotron Light Sources and Free-Electron Lasers, edited by E. Jaeschke, S. Khan, J. Schneider & J. Hastings. Cham: Springer International Publishing.]; Honkimäki et al., 2020[Honkimäki, V., Tafforeau, P. & Wright, J. (2020). Synchrotron Radiat. News, 33(6), 5-10.]) and especially the high-energy range (≥70 keV) (Bravin et al., 2013[Bravin, A., Coan, P. & Suortti, P. (2013). Phys. Med. Biol. 58, R1-R35.]), which are suitable for biomedical imaging of large soft tissue samples, little is known about the imaging capacity imposed by the cascading effects from these physical interactions. Especially within the energy range 60–150 keV, typical for clinical applications (Wu et al., 2005[Wu, X., Liu, H. & Yan, A. (2005). Opt. Lett. 30, 379.]), high X-ray transmission enables low-dose imaging at a high signal-to-noise ratio using the phase-contrast information of weakly absorbing tissues (Bravin et al., 2013[Bravin, A., Coan, P. & Suortti, P. (2013). Phys. Med. Biol. 58, R1-R35.]). Additionally, these higher X-ray energies can be effectively employed for imaging large soft tissue samples, such as human organs (Walsh et al., 2021[Walsh, C. L., Tafforeau, P., Wagner, W. L., Jafree, D. J., Bellier, A., Werlein, C., Kühnel, M. P., Boller, E., Walker-Samuel, S., Robertus, J. L., Long, D. A., Jacob, J., Marussi, S., Brown, E., Holroyd, N., Jonigk, D. D., Ackermann, M. & Lee, P. D. (2021). Nat. Methods, 18, 1532-1541.]). Here, X-ray absorption and the subsequent radiation-induced processes are led by Compton scattering compared with lower photon energies, where the photoelectric effect dominates, especially for light elements within soft tissues (Bras et al., 2021[Bras, W., Myles, D. A. A. & Felici, R. (2021). J. Phys. Condens. Matter, 33, 423002.]; Hubbell, 1999[Hubbell, J. H. (1999). Phys. Med. Biol. 44, R1-R22.]). For long-term imaging, which can last hours to days, bubble formation has only been briefly mentioned with X-rays in the 20–35 keV range (Saccomano et al., 2018[Saccomano, M., Albers, J., Tromba, G., Dobrivojević Radmilović, M., Gajović, S., Alves, F. & Dullin, C. (2018). J. Synchrotron Rad. 25, 1153-1161.]; Mittone et al., 2020[Mittone, A., Fardin, L., Di Lillo, F., Fratini, M., Requardt, H., Mauro, A., Homs-Regojo, R. A., Douissard, P.-A., Barbone, G. E., Stroebel, J., Romano, M., Massimi, L., Begani-Provinciali, G., Palermo, F., Bayat, S., Cedola, A., Coan, P. & Bravin, A. (2020). J. Synchrotron Rad. 27, 1347-1357.]). To our knowledge, no systematic investigation has yet been reported to quantify the bubbling phenomenon in the bioimaging context and at high energies very far off-resonance to sample composition.

Understanding the factors influencing X-ray-induced bubble formation is essential for the optimization of sample preparation and imaging protocols to improve the imaging efficiency and alleviate the failure rate in large-scale projects. To meet the challenge, we used a parallel X-ray beam with typical characteristics for large sample tomography to trigger the bubble formation during in-line phase-contrast cine­radiography (time-resolved radiography) of partially ethanol-dehydrated tissue samples. We combined micro-gas chromatography (µGC) (Lussac et al., 2016[Lussac, E., Barattin, R., Cardinael, P. & Agasse, V. (2016). Crit. Rev. Anal. Chem. 46, 455-468.]; Regmi & Agah, 2018[Regmi, B. P. & Agah, M. (2018). Anal. Chem. 90, 13133-13150.]) with an X-ray imaging beamline to perform online detection of volatile chemical species (such as N2, O2, H2O and EtOH).

We hypothesized that: (i) vacuum degassing during sample preparation increases the sample resistance to bubble formation; (ii) bubble formation and dynamics depend on the tissue type, a combined factor of tissue composition and microstructure; (iii) bubble growth would be constrained by the geometry of the tissue microstructure in which they formed. From the analysis of the two simultaneous time-resolved imaging and µGC measurements, we identified two factors contributing to the bubble formation: (i) residual dissolved gas in the samples; (ii) X-ray-induced vaporization of the solvents. We also found that in degassed samples, although bubble nucleation was delayed and the final bubble load was lower, the bubbles grew faster initially. The results map out the dose regime for uninterrupted phase-contrast imaging of soft tissues. Moreover, by analysis of global and local bubble dynamics, we identify bubble nucleation sites and distinguish site-specific bubble dynamics pertaining to the geometric constraints in the surrounding space. The collective experimental evidence points to a bubble formation process facilitated by photoionization of the solvents.

2. Materials and methods

2.1. Sample preparation

The lung and the brain used for the experiment were obtained from two organ donors registered at the Laboratoire d'Anatomie Des Alpes Françaises (LADAF) in Grenoble, France. Dissections were performed respecting current French legislation for body donation. Body donation was based on free consent by the donors antemortem. All dissections respected the memory of the deceased. The post-mortem study was conducted according to QUACS (Quality Appraisal for Cadaveric Studies) scale recommendations (Wilke et al., 2015[Wilke, J., Krause, F., Niederer, D., Engeroff, T., Nürnberger, F., Vogt, L. & Banzer, W. (2015). J. Anat. 226, 440-446.]). The postmortem processing of organs (human brain and lung) follows the procedure involving formalin fixation and ethanol dehydration described in detail elsewhere (Walsh et al., 2021[Walsh, C. L., Tafforeau, P., Wagner, W. L., Jafree, D. J., Bellier, A., Werlein, C., Kühnel, M. P., Boller, E., Walker-Samuel, S., Robertus, J. L., Long, D. A., Jacob, J., Marussi, S., Brown, E., Holroyd, N., Jonigk, D. D., Ackermann, M. & Lee, P. D. (2021). Nat. Methods, 18, 1532-1541.]; Xian et al., 2022[Xian, R. P., Walsh, C. L., Verleden, S. E., Wagner, W. L., Bellier, A., Marussi, S., Ackermann, M., Jonigk, D. D., Jacob, J., Lee, P. D. & Tafforeau, P. (2022). Sci. Data, 9, 264.]; Brunet et al., 2023[Brunet, J., Walsh, C. L., Wagner, W. L., Bellier, A., Werlein, C., Marussi, S., Jonigk, D. D., Verleden, S. E., Ackermann, M., Lee, P. D. & Tafforeau, P. (2023). Nat. Protoc. 18, 1441-1461.]). The human brain and lung samples were cut into ∼20 mm-thick slices with a diameter of ∼70 mm [see Fig. S1 of the supporting information (SI)]. The slices fit laterally into the cylindrical plastic containers such that the section plane is parallel with the lid to simulate the imaging geometry in tomography (Walsh et al., 2021[Walsh, C. L., Tafforeau, P., Wagner, W. L., Jafree, D. J., Bellier, A., Werlein, C., Kühnel, M. P., Boller, E., Walker-Samuel, S., Robertus, J. L., Long, D. A., Jacob, J., Marussi, S., Brown, E., Holroyd, N., Jonigk, D. D., Ackermann, M. & Lee, P. D. (2021). Nat. Methods, 18, 1532-1541.]) and to facilitate gas escape as gasses are formed on the tissue interior and surfaces. The tissue slices were immersed in 70% ethanol solution in water and immobilized with crushed agar (Walsh et al., 2021[Walsh, C. L., Tafforeau, P., Wagner, W. L., Jafree, D. J., Bellier, A., Werlein, C., Kühnel, M. P., Boller, E., Walker-Samuel, S., Robertus, J. L., Long, D. A., Jacob, J., Marussi, S., Brown, E., Holroyd, N., Jonigk, D. D., Ackermann, M. & Lee, P. D. (2021). Nat. Methods, 18, 1532-1541.]; Xian et al., 2022[Xian, R. P., Walsh, C. L., Verleden, S. E., Wagner, W. L., Bellier, A., Marussi, S., Ackermann, M., Jonigk, D. D., Jacob, J., Lee, P. D. & Tafforeau, P. (2022). Sci. Data, 9, 264.]; Brunet et al., 2023[Brunet, J., Walsh, C. L., Wagner, W. L., Bellier, A., Werlein, C., Marussi, S., Jonigk, D. D., Verleden, S. E., Ackermann, M., Lee, P. D. & Tafforeau, P. (2023). Nat. Protoc. 18, 1441-1461.]). The non-tissue controls contain only the agar–ethanol mixture. Half of the containers were `highly' degassed using a diaphragm pump while the other half were not. During the vacuum degassing, the dissolved gas vaporized and bubbles appeared. The endpoint of vacuum degassing was determined by two observations: the emergence of bubbles after 90 s and a noticeable reduction in bubble formation upon visual examination. Details on the sample preparation and mounting are provided in SI Section S1.

2.2. In-line phase-contrast cineradiography

X-ray phase-contrast radiography and cineradiography experiments were carried out at the ESRF BM05 beamline using a polychromatic source. The X-ray white beam dimensions were 51.2 mm × 5.2 mm and was attenuated by 40 mm SiO2 and 1.53 mm aluminium for an average energy of 82 keV. Only the field of view was illuminated; the rest of the X-ray beam was stopped with four-blade tungsten slits. The radiographs were directly recorded with the parallel beam configuration shown in Fig. 1[link](c) using a 2 mm-thin LuAG:Ce scintillator (lutecium-aluminium garnet doped with cerium, custom-made by Crytur, Czechia) and an sCMOS light sensor (PCO edge 4.2 Camera Link HS, PCO Imaging, Germany). The measurement configuration has a propagation distance (between the sample on the rotation stage and the detector) of 3475 mm, resulting in an isotropic pixel size of 25 µm for all radiographs. For each sample container, we started by locating the sample position with static phase-contrast radiographs. To trace the onset and evolution of X-ray-induced bubbles, cineradiographs were recorded with a data acquisition rate of three images per second for at least ∼10 min after the first bubble appeared within the field of view. The experimental hutch was kept at a constant temperature of 23°C.

2.3. Real-time gas chromatography

In the experiments, we used a portable commercial micro-gas chromatograph (ChromPix2, APIX Analytics, France) along with the data acquisition software DataApex Clarity v8.5. Four detection modules (MS5A, PDMS5, PDMS10, PPU), each containing a separate column as the stationary phase, were used to cover a wide range of detectable molecular species. We recovered the relative concentrations of EtOH and H2O from the µGC module PDMS10, and those for N2 and O2 from the module MS5A. The modules do not detect H2 due to the capacity limit, but the detected O2 and volatile organic compounds were used to monitor the experiment. To improve gas detection, a reservoir of He gas was used as the carrier gas to continuously flush the volume within the cylindrical housing [see Fig. 1[link](d) and SI Fig. S2(a)], which functions as a dynamical headspace, to inject the escaped gas into the chromatograph. A pump was attached to the exhaust of the µGC to facilitate the gas extraction. During operando measurements, each round of gas elution through the four detection modules required about 2.4 min.

2.4. Computational analysis

Multiple flat-field images from static radiographs and cineradiographs have been used to estimate the bubble volume without explicit tomographic scans, which is possible after calculating and subtracting the absorption profile of the agar and tissue from the overall profile (see SI Section S2). The volume calculation used the direct inversion of the Beer–Lambert law. The bubble circularity in constrained environments is calculated using 4πA/C2, where A and C are, respectively, the area and perimeter of the specific bubble obtained from image segmentation.

3. Results and discussion

In the present study, we monitored the nucleation and growth of gas bubbles in soft tissue samples triggered by polychromatic synchrotron X-ray irradiation centered at 82 keV. Simultaneously, the X-ray beam was also used for phase-contrast cineradiography of the samples accumulated through free-space propagation of the transmitted beam over ∼5 m of air in the experimental hutch (Walsh et al., 2021[Walsh, C. L., Tafforeau, P., Wagner, W. L., Jafree, D. J., Bellier, A., Werlein, C., Kühnel, M. P., Boller, E., Walker-Samuel, S., Robertus, J. L., Long, D. A., Jacob, J., Marussi, S., Brown, E., Holroyd, N., Jonigk, D. D., Ackermann, M. & Lee, P. D. (2021). Nat. Methods, 18, 1532-1541.]) [see Fig. 1[link](d)]. In total, two thick slices of human lung and brain tissues, obtained from similar anatomical locations in each organ, were used for our study, without exogenous staining, along with two non-tissue controls filled only with agar–ethanol mixtures [see Section 2 (Materials and methods)[link], and SI Fig. S1 and Section S1]; in each case, one of the two samples was vacuum degassed during preparation (see Section 2[link]). Bubbles appeared in all tested samples (see SI Fig. S2) after at most ∼21 min of X-ray irradiation. The measured static radiographs and cineradiographs were preprocessed to enhance the contrast of relevant sample composition (agar, tissue and gas bubbles) by multiple flat-field correction methods (see SI Section S2). A compilation of characteristic radiographic frames for a lung sample is shown in Fig. 2[link] with more shown in SI Fig. S3.

[Figure 2]
Figure 2
Schematic illustrating the timescales observed in the experiments. The key time points include radiation on and off times (tron and troff) and bubble onset time (tbo). The time courses include irradiation time (trad) and the time before and after bubble onset (tbbo and tabo). Bubbles that emerged sequentially (using round ones as examples) are indicated with different colors to distinguish from one another. The in-line phase-contrast radiographs in (b) each have a field of view of 50 mm (width) by 4 mm (height). Frame 0 shows the lung tissue context in a static radiograph, while frames 1–4 are cineradiographs at different time points after bubble onset and subtraction of the tissue context. All images in (b) are obtained after context-specific flat-field corrections (see SI Section S2). (c) Quantification of the global bubble evolution using their time-dependent volume within the field of view and (d) the cumulative volume. The temporal locations of the frames in (b) are indicated in (c) and (d) as vertical dashed lines.

To unambiguously describe bubble dynamics, we define four terms – tbo (time of bubble onset), tbbo (time before bubble onset), tabo (time after bubble onset) and trad (irradiation time) – shown in the schematic in Fig. 2[link](a). From our observation, bubbles emerge and grow sequentially at multiple sites [see Fig. 2[link](a) and SI Videos S1 to S6]. Bubbles are usually formed in the field of view of the irradiating X-ray beam, then they migrate to the top, to the container lid. An example of bubble formation and evolution is shown in Figs. 2[link](b)–2(d) for a human lung tissue sample, where the bubbles first appeared in the alveoli. We quantify the bubble volume growth using the instantaneous time-dependent bubble volume (within the field of view), V(t), Fig. 2[link](c), or the cumulative bubble volume (including bubbles that have left the field of view), VC(t). They are related according to

[{V}_{\rm C}\left(t\right) = \int\limits_{0}^{t} V\left(\tau\right)\, {\rm{d}}\tau = \int\limits_{t^{\,\rm{bo}}}^{t} V\left(\tau\right) \, {\rm{d}}\tau, \eqno(1)]

where tbo refers to the bubble onset time [see Fig. 2[link](a)]. We observe that the overall bubble growth exhibits a power-law dependence over time and tends towards saturation in the end. The turning point at around 76 min since the start of irradiation corresponds to the time point where most of the lung tissue's air spaces within the field of view of the X-ray beam are filled with gas bubbles. To identify tbo, we manually selected the cineradiograph when visible bubbles first appeared within the field of view of the X-ray beam.

3.1. Degassing increases time to nucleation and reduces bubble load for a given X-ray dose

tbbo shown in Fig. 3[link](a) indicates that the degassing procedure substantially increases the time before bubble nucleation for human brain and lung tissues, as well as for the non-tissue controls containing only the agar–ethanol mixture. The increase of tbbo in degassed compared with non-degassed tissues demonstrates quantitatively that vacuum degassing is essential for avoiding bubble formation during prolonged X-ray scans. Over the course of a scan, at any given irradiation time trad, the degassed samples consistently have a lower cumulative gas volume (SI Fig. S5) and the excess gas volume is positive [Fig. 3[link](b)]. Moreover, the difference between degassed and non-degassed samples is more pronounced (in both nucleation time and difference between highly and non-degassed samples) in the tissue samples derived from the human lung than those from the brain, indicating a relation to their difference in gas solubility and tissue microstructures (Weathersby & Homer, 1980[Weathersby, P. K. & Homer, L. D. (1980). Undersea Biomed. Res. 7, 277-296.]). These findings confirm that vacuum degassing enhances the sample resistance to bubble formation [hypothesis (i)] and that the bubbling process depends on the tissue type [hypothesis (ii)].

[Figure 3]
Figure 3
Quantitative characteristics of bubble onset and sample dependence after X-ray irradiation. (a) Bubble onset time [tbo in Fig. 2[link](a)] and X-ray dose deposited into different samples. Compared with non-degassed samples, the degassed samples show markedly delayed bubble onset and therefore higher dose threshold associated with bubble formation. (b) The excess in cumulative bubble volumes for three settings are calculated as a function of tabo, showing an increase until saturation, followed by a downward trend. (c) The initial ∼11 min of bubble growth measured against the time after bubble onset [tabo in Fig. 2[link](a)] shows a speed-up for highly degassed samples. The color choices in (ac) are consistent to display their interrelationship.

3.2. Once formed, bubbles in highly degassed sample initially grow more quickly than in non-degassed sample

For all three pairs of tissue, the bubble time course dynamics can be adjusted for the time of bubble onset to facilitate comparison of the early bubble growth dynamics. After adjusting for the bubble onset times [see Fig. 3[link](b)], we observed a faster initial bubble growth rate in highly degassed than non-degassed samples [Fig. 3[link](c)]. To quantify the initial growth trend of X-ray-induced bubbles, we approximate the cumulative bubble volume by a power-law relation,

[V_{\rm C}\left(t\right) \simeq {\rm{rect}}\left(t-t^{\,\rm{bo}}\right)\, t^{\,\alpha}. \eqno(2)]

Here, rect is a window function, the terms tbo represent the bubble onset (bo) time and α is the growth exponent. Fitting of equation (2)[link] to the data up to 10 min following bubble onset yields a consistent growth exponent α ≃ 3.0 for highly degassed samples while in non-degassed samples α varies by at least 0.4, exhibiting strong dependence on the sample (see SI Table S2). Since dissolved gas modifies the liquid's thermodynamic landscape (Jones et al., 1999[Jones, S. F., Evans, G. M. & Galvin, K. P. (1999). Adv. Colloid Interface Sci. 80, 27-50.]), the noticeable change in kinetics between highly degassed and non-degassed samples indicates the distinct metastable states that the embedding solution was in immediately before bubble onset. In addition, we calculated the difference in terms of cumulative bubble volume as shown in Fig. 3[link](b). For all control pairs, the excess increases until a certain threshold is reached before decreasing.

3.3. Bubble growth is geometrically constrained by sample microstructure

When bubbles nucleate in less constrained spaces, such as on the material (tissue and crushed agar) surfaces or in the solution phase of the embedding media (ethanol), they aggregate, coalesce and often move upwards out of the imaging field of view. These less spatially constrained bubbles tend to be more globular and grow more uniformly, whereas the bubbles formed within void spaces in the tissue interior such as empty blood vessels or the lung's air-contacting bronchi are more likely to be trapped in situ (bubble entrainment). The entrapped bubbles take on the shape of the surrounding material confining their growth and are generally highly nonspherical. These distinct bubble dynamics all contribute to the overall growth shown in Figs. 2[link] and 3[link]. Once the X-ray beam is shut off, the bubbling process keeps developing but gradually subsides as the excess energy dissipates, which can take several minutes in our experiments, as checked by taking static radiographs at later times. The appearances of samples before and after X-ray irradiation are compared in SI Fig. S2, where bubbles are visible around and above the tissue sample up until the container lid.

Understanding the site-specific bubble dynamics can help elucidate the nature of the bubble formation process (Brennen, 2013[Brennen, C. E. (2013). Cavitation Bubble Dynamics. Cambridge University Press.]). To this end, we selected representative bubbles from each sample that were spatially separated from other bubbles within the recorded radiographs (see Fig. 4[link]). For each case, we calculated the bubble circularity (see Section 2[link]) and area over time after image segmentation. A circularity of 1 indicates a perfect circle, whereas the closer it approaches 0 the more eccentric the shape becomes. From the shape analysis of the bubble growth, three distinctive scenarios emerge: (i) Unrestricted 3D growth of bubbles [Figs. 4[link](a)–4(c)] that nucleated within the gaps of crushed agar, showing a nearly constant circularity over time. The relationship between bubble area (A) and the time after bubble onset (tabo, here referring to the specific bubble's timescale) is Atabo, indicating that its radial growth rate [{\rm{d}}R/{\rm{d}}t][{(t^{\,\rm{abo}})}^{-1/2}], which is consistent with vapor (Prosperetti, 2017[Prosperetti, A. (2017). Annu. Rev. Fluid Mech. 49, 221-248.]) or diffusion-driven growth (Brennen, 2013[Brennen, C. E. (2013). Cavitation Bubble Dynamics. Cambridge University Press.]). (ii) Growth within a large blood vessel [Figs. 4[link](d)–4(f)] in the brain tissue (∼100 µm diameter), showing a continuous decrease in circularity that correlates with bidirectional expansion within the tubular vessel, which resembles the behavior of intravascular gas embolism (Branger & Eckmann, 1999[Branger, A. B. & Eckmann, D. M. (1999). J. Appl. Phys. 87, 1287-1295.]). (iii) Stepped growth of bubbles that indicates the distinct growth rates in a multi-compartmental structure like the alveoli and the lung's peripheral air spaces (Haefeli-Bleuer & Weibel, 1988[Haefeli-Bleuer, B. & Weibel, E. R. (1988). Anat. Rec. 220, 401-414.]) [Figs. 4[link](g)–4(i)]. The step-like feature in time-dependent circularity and bubble area correlate with the sequential expansion of the bubble into nearby alveoli further and further away from the nucleation site. Gas expansion within neighboring pulmonary alveoli is the fastest among the three scenarios [increasing by ∼4 × 106 µm3 in less than 2 min as in Fig. 4[link](c)] due to their optimized anatomical design that facilitates alveolar gas exchange (Sapoval et al., 2002[Sapoval, B., Filoche, M. & Weibel, E. R. (2002). Proc. Natl Acad. Sci. USA, 99, 10411-10416.]).

[Figure 4]
Figure 4
Constrained bubble dynamics in different microscopic void spaces, including (ac) regions between crushed agar, (df) within brain vasculature and (gi) within alveoli of the lung. (a, d, g) Schematics showing the local spatial geometry where the bubbles (white or light gray inside in phase contrast) are formed. (b, e, h) The extracted growth dynamics of the bubbles within these spaces are quantified using time-dependent circularity and bubble area. (c, f, i) Representative radiographic frames showing the morphological changes of the specific bubble dynamics. The respective time points are indicated by vertical dashed lines in (b), (e) and (h), respectively. The white scale bars represent 500 µm.

3.4. Gas analysis shows changes in relative solvent concentration during bubbling

The µGC-based gas detection setup is briefly described in Section 2[link]. The detected gasses come from two sources: (i) the dynamical headspace within the plastic housing around the sample container, and (ii) the gasses generated within the sample container, including dissolved gas, vapor, and gaseous or volatile end products from potential photoreactions. Chromatographic monitoring provides a way to examine the bubble content as they escape the system on the second to minute timescale. Therefore, the detection scheme naturally filters out short-lived, highly reactive reaction intermediates as well as trace gasses since none of them is a main contributor to bubble formation macroscopically. In our case, four detection modules were used in the micro-gas chromatograph to cover different ranges of chemicals (see SI Section S4.1). As presented in Fig. 5[link], the chromatograms show clear signatures of evaporated solvent (EtOH and H2O) and gasses from ambient air or dissolved gasses in tissue (primarily N2 and O2). Although dissolved O2 and N2 concentrations differ with tissue composition (Weathersby & Homer, 1980[Weathersby, P. K. & Homer, L. D. (1980). Undersea Biomed. Res. 7, 277-296.]), we have observed that the relative concentrations of N2 and O2 detected by µGC are essentially unchanged in all cases before and during sustained bubbling under X-ray irradiation, as shown in Fig. 5[link]. This contrasts with the behavior of evaporated solvents from µGC. Specifically, EtOH shows an increase in its relative concentration for all samples except the non-degassed agar, whereas it generally decreases for H2O. For each sample, the changes took place around the corresponding observed tbo, which is largely consistent for all pairs of samples, without a noticeable dependence on sample type. This indicates that the gas from X-ray induced bubbles largely comes from solvent vapor. Moreover, within our detection sensitivity limit, no significant signals of other chemical species, such as the radiolytic product acetaldehyde (CH3CHO) from EtOH, have been detected, indicating the relative radiation stability of agar and solvents (see SI Section S4.2).

[Figure 5]
Figure 5
Gas evolution around the bubble onset time (tbo) during X-ray irradiation for (ab) agar samples, (cd) human brain tissue samples and (ef) human lung tissue samples. Four dominant chemical species detected by the micro-gas chromatograph, including N2, O2, EtOH and H2O, are shown here in their relative concentrations (rel. conc.) at 6 min, 3 min before bubble onset and 5 min, 10 min after it. The relative concentrations are separated into two sets corresponding to the two modules: MS5A measured O2 and N2 concentrations (yellow), while PDMS10 measured EtOH, H2O and O2 + N2 (purple). The relative concentrations are expressed on a normalized scale, where 0 indicates 0% concentration and 1 corresponds to 100% concentration. For each type of gas, the corresponding tbo is drawn in the figures with vertical red lines. The general behavior before and after bubble onset is that the relative concentrations of dissolved gasses (N2 and O2) remain constant, while the solvent vapor (EtOH and H2O) shows noticeable changes.

3.5. Mechanisms driving bubble nucleation and growth

In addition to our initial hypotheses regarding sample preparation and tissue composition, our study enables the investigation of the mechanisms that underlie bubble formation and growth in the high-energy X-ray regime. Our quantitative observations for our experimental conditions led us to consider a few plausible underlying mechanisms, which can come from chemistry and heating (thermal or nonthermal). The mechanisms we considered were (i) accumulated photochemical effects, (ii) dose-dependent solvent heating effects, and (iii) phase transition in the gel embedding. Regarding scenario (i), the most likely reactions are the radiolysis of EtOH and H2O, which produce gasses (H2, O2, CH3CHO and H2O as volatile primary products), radical ions, and oxidized solvent as end products (Meents et al., 2010[Meents, A., Gutmann, S., Wagner, A. & Schulze-Briese, C. (2010). Proc. Natl Acad. Sci. USA, 107, 1094-1099.]; Le Caër, 2011[Le Caër, S. (2011). Water, 3, 235-253.]; Freeman, 1974[Freeman, G. R. (1974). Radiation Chemistry of Ethanol: A Review of Data on Yields, Reaction Rate Parameters, and Spectral Properties of Transients. National Institute of Standards and Technology, Gaithersburg, MD, USA.]; Sazonov et al., 2015[Sazonov, A. B., Marchenko, N. V. & Nikitin, A. V. (2015). High Energy Chem. 49, 223-233.]). Since the high-energy X-rays used for imaging are very far off resonance to sample composition, we expect the gas contribution from direct water and ethanol splitting with X-rays (Mao et al., 2006[Mao, W. L., Mao, H., Meng, Y., Eng, P. J., Hu, M. Y., Chow, P., Cai, Y. Q., Shu, J. & Hemley, R. J. (2006). Science, 314, 636-638.]) to be low, albeit nonvanishing. This stems from the two-order-of-magnitude reduction of the photoelectric effect cross-section between X-rays in the energy range 80–100 keV and 10–30 keV for light elements which constitute soft tissues (Hubbell, 1999[Hubbell, J. H. (1999). Phys. Med. Biol. 44, R1-R22.]). In fact, an earlier experiment on ice showed that X-ray-induced H2O decomposition is undetectable with X-ray energies above 30 keV (Mao et al., 2006[Mao, W. L., Mao, H., Meng, Y., Eng, P. J., Hu, M. Y., Chow, P., Cai, Y. Q., Shu, J. & Hemley, R. J. (2006). Science, 314, 636-638.]). In our case, the reasoning is supported by the µGC results, which identify X-ray-induced vaporization (Weon et al., 2011[Weon, B. M., Lee, J. S., Je, J. H. & Fezzaa, K. (2011). Phys. Rev. E, 84, 032601.]) as a primary source of gas escape.

To evaluate (ii) and (iii), we performed dosimetry measurements with an ionization chamber dosimeter and numerical estimation (see SI Section S3). With a measured dose rate of 36.8 Gy s−1, we found that the accumulated surface dose on the sample ranges between 15.5 kGy (non-degassed agar) and 46.4 kGy (highly degassed lung) just before bubble onset [see Fig. 3[link](a) and SI Table S3]. The dosimetry data are then used to estimate the temperature change (see SI Section S3): assuming no heat exchange, the thermal load imparted to the sample generally creates a temperature increase within the X-ray field of view of up to about 11°C, if assuming only H2O, or 19°C, if assuming only EtOH. These estimations correspond to the maximum possible temperature change. Although detailed dosimetry calibrations are beyond the scope of this work, our estimation provides a sensible upper bound on these values. Therefore, the macroscopic metastable state at bubble onset differs from the two prominent examples of thermally induced bubble formation involving electromagnetic radiation: (a) resonant heating which produces plasmonic microbubbles from water vaporization observed in solvated gold nanoparticles (Wang et al., 2018[Wang, Y., Zaytsev, M. E., Lajoinie, G., The, H. L., Eijkel, J. C. T., van den Berg, A., Versluis, M., Weckhuysen, B. M., Zhang, X., Zandvliet, H. J. W. & Lohse, D. (2018). Proc. Natl Acad. Sci. USA, 115, 7676-7681.]); (b) the bubble-chamber phenomenon (Roy, 2001[Roy, S. C. (2001). Radiat. Phys. Chem. 61, 271-281.]; d'Errico, 2001[Errico, F. d' (2001). Nucl. Instrum. Methods Phys. Res. B, 184, 229-254.]), which requires a superheated liquid medium to be maintained between its boiling and critical temperature for the effect to take place. For 70% EtOH, the boiling point is over 78°C at ambient pressure (https://webbook.nist.gov/cgi/cbook.cgi?ID=64-17-5), which is inconsistent with our experimental condition. However, rapid photoionization can produce heating effects through disruption of the coordination environment in the solvation shell (Beyerlein et al., 2018[Beyerlein, K. R., Jönsson, H. O., Alonso-Mori, R., Aquila, A., Bajt, S., Barty, A., Bean, R., Koglin, J. E., Messerschmidt, M., Ragazzon, D., Sokaras, D., Williams, G. J., Hau-Riege, S., Boutet, S., Chapman, H. N., Tîmneanu, N. & Caleman, C. (2018). Proc. Natl Acad. Sci. USA, 115, 5652-5657.]) or lowering of the vaporization enthalpy (Weon et al., 2008[Weon, B. M., Je, J. H., Hwu, Y. & Margaritondo, G. (2008). Phys. Rev. Lett. 100, 217403.], 2011[Weon, B. M., Lee, J. S., Je, J. H. & Fezzaa, K. (2011). Phys. Rev. E, 84, 032601.]). In our case, it is likely that the exsolution of dissolved gas in tissue due to a moderate temperature change or trace gas generated through photochemical reactions seeded the bubble formation in the solvent, which is further promoted by a photoionization-disrupted local solvation environment to rupture the bulk liquid.

For scenario (iii), the working hypothesis is that the agar may undergo thermoreversible sol–gel transition due to X-ray-induced heating, resulting in the release of entrapped gas. This behavior has been observed at much lower X-ray energies (∼30 keV), resulting in melting of the embedding agar gel during imaging (Mittone et al., 2020[Mittone, A., Fardin, L., Di Lillo, F., Fratini, M., Requardt, H., Mauro, A., Homs-Regojo, R. A., Douissard, P.-A., Barbone, G. E., Stroebel, J., Romano, M., Massimi, L., Begani-Provinciali, G., Palermo, F., Bayat, S., Cedola, A., Coan, P. & Bravin, A. (2020). J. Synchrotron Rad. 27, 1347-1357.]). However, in our case, the crushed agar has been degassed after gelling and before its use in sample preparation. At the considerably higher X-ray energy we used for radiography, no change in the consistency of the agar gel was observed from before the X-ray beam is switched on and immediately after the beam is shut off. Moreover, due to the large thermal hysteresis of agar, its melting temperature is much higher than the gel-setting temperature, therefore the very moderate temperature change we estimated before tbo would unlikely initiate melting.

3.6. Discussion

Our estimation of the bubble onset and volume estimation is only accounting for those within the field of view of the X-ray beam, hence we exclude the bubbles generated from scattered X-rays. Nevertheless, we observe that X-ray-induced bubble formation appears to have a dose threshold in the 104 kGy range for in-line radiography. Vacuum degassing delays the bubble onset time, and reduces bubble load over the timescale of a typical scan. The degassing process also leads to faster bubble growth than non-degassed samples at this delayed time. These results, on the one hand, complement existing discussions of the dose-resolution trade-off in X-ray nanoimaging of single cells and thin tissues and in macromolecular crystallography (Howells et al., 2009[Howells, M. R., Beetz, T., Chapman, H. N., Cui, C., Holton, J. M., Jacobsen, C. J., Kirz, J., Lima, E., Marchesini, S., Miao, H., Sayre, D., Shapiro, D. A., Spence, J. C. H. & Starodub, D. (2009). J. Electron Spectrosc. Relat. Phenom. 170, 4-12.]; Jacobsen, 2020[Jacobsen, C. (2020). X-ray Microscopy, pp. 457-495. Cambridge University Press.]), where samples (at only up to millimetres in size) are typically kept in a frozen-hydrated or freeze-dried state. On the other hand, they relate to the emerging field of X-ray virtual histology (Walsh et al., 2021[Walsh, C. L., Tafforeau, P., Wagner, W. L., Jafree, D. J., Bellier, A., Werlein, C., Kühnel, M. P., Boller, E., Walker-Samuel, S., Robertus, J. L., Long, D. A., Jacob, J., Marussi, S., Brown, E., Holroyd, N., Jonigk, D. D., Ackermann, M. & Lee, P. D. (2021). Nat. Methods, 18, 1532-1541.]; Bravin et al., 2013[Bravin, A., Coan, P. & Suortti, P. (2013). Phys. Med. Biol. 58, R1-R35.]; Busse et al., 2018[Busse, M., Müller, M., Kimm, M. A., Ferstl, S., Allner, S., Achterhold, K., Herzen, J. & Pfeiffer, F. (2018). Proc. Natl Acad. Sci. USA, 115, 2293-2298.]; Töpperweien et al., 2018[Töpperwien, M., van der Meer, F., Stadelmann, C. & Salditt, T. (2018). Proc. Natl Acad. Sci. USA, 115, 6940-6945.]), where the balance of sample integrity and imaging throughput requires consideration of radiation–matter interaction across various scales determined by the biological questions. Since bubbles can cause local deformation which may lead to damage in soft materials including tissues (Barney et al., 2020[Barney, C. W., Dougan, C. E., McLeod, K. R., Kazemi-Moridani, A., Zheng, Y., Ye, Z., Tiwari, S., Sacligil, I., Riggleman, R. A., Cai, S., Lee, J., Peyton, S. R., Tew, G. N. & Crosby, A. J. (2020). Proc. Natl Acad. Sci. USA, 117, 9157-9165.]; Hasan et al., 2021[Hasan, F., Al Mahmud, K. A. H., Khan, M. I., Patil, S., Dennis, B. H. & Adnan, A. (2021). Multiscale Sci. Eng. 3, 67-87.]) from the pressure exerted on them during cavitation, collapse or subsequent bubble entrainment, our results provide the empirical foundation for developing precautionary measures, such as tissue degassing, pressurization, temperature stabilization, to mitigate or postpone bubble formation, thereby reducing the measurement failure rate. The methods described here may also be used to further investigate microbubble formation and growth phenomena in various tissues relevant for clinical models. The examples include air embolism (Muth & Shank, 2000[Muth, C. M. & Shank, E. S. (2000). N. Engl. J. Med. 342, 476-482.]; Branger & Eckmann, 1999[Branger, A. B. & Eckmann, D. M. (1999). J. Appl. Phys. 87, 1287-1295.]) from positive pressure ventilation or after scuba diving accidents, where alveolar gas ruptures into neighboring capillaries due to an increase in gas volume (Russi, 1998[Russi, E. W. (1998). Thorax, 53, S20-S24.]), and decompression sickness, where the mechanism and progression of off-gassing from tissue and vasculature remains unproven (Papadopoulou et al., 2013[Papadopoulou, V., Eckersley, R. J., Balestra, C., Karapantsios, T. D. & Tang, M. (2013). Adv. Colloid Interface Sci. 191-192, 22-30.]). In both cases, constructing microscopically accurate physiological simulations requires empirical parameters that are often hard to obtain in parenchymal tissues by conventional means.

Beyond the context of bioimaging, spontaneous bubble formation during X-ray experiments has also been briefly reported in X-ray spectroscopy (Mesu et al., 2006[Mesu, J. G., Beale, A. M., de Groot, F. M. F. & Weckhuysen, B. M. (2006). J. Phys. Chem. B, 110, 17671-17677.]) and real-time imaging of electrodeposition (Tsai et al., 2002[Tsai, W. L., Hsu, P. C., Hwu, Y., Chen, C. H., Chang, L. W., Je, J. H., Lin, H. M., Groso, A. & Margaritondo, G. (2002). Nature, 417, 139.]) and batteries (Charalambous et al., 2021[Charalambous, H., Abraham, D. P., Dunlop, A. R., Trask, S. E., Jansen, A. N., Tanim, T. R., Chinnam, P. R., Colclasure, A. M., Xu, W., Yakovenko, A. A., Borkiewicz, O. J., Gallington, L. C., Ruett, U., Wiaderek, K. M. & Ren, Y. (2021). J. Power Sources, 507, 230253.]) involving liquid electrolytes. In these scenarios, the environment is also heterogeneous and bubbles likewise produce undesired and sometimes deleterious effects for the precise characterization and stable operation of devices. However, because of the complexity of the liquid environment and gasses produced during electrochemical operations (Rowden & Garcia-Araez, 2020[Rowden, B. & Garcia-Araez, N. (2020). Energy Rep. 6, 10-18.]), it remains exceedingly difficult to separate the sources of bubbles. Our observations in soft biological tissues and gels reaffirm the proposition that X-rays may not be treated solely as a passive probe under intense or prolonged irradiation (Bras et al., 2021[Bras, W., Myles, D. A. A. & Felici, R. (2021). J. Phys. Condens. Matter, 33, 423002.]), although isolating bubble sources will require subsequent studies in simplified model systems. The set of control experiments reported here demonstrates that bubble formation remains an issue even at high X-ray energies, when sufficient dose is deposited into the sample and its embedding environment, regardless of the initial condition.

3.7. Limitations of the study

Synchrotron experiments are typically strongly constrained by time, which precludes the exhaustive testing and optimization of many experimental factors. The current study focuses on examining the degassing time, the bubble growth characteristics, and the tissue type dependence on the bubble onset. Other parameters may influence bubble formation but were not tested include the dependence on X-ray energy (e.g. in the 30–80 keV range), the synchrotron electron bunch structure, sample and container size, and embedding medium characteristics (e.g. concentration, viscosity, pH, etc). Nevertheless, our analysis indicates that under similar synchrotron X-ray irradiation and environmental conditions, the vaporization enthalpy of the liquid embedding medium and the sample property may be key factors for determining tbbo, the quantity we intend to maximize in uninterrupted imaging. These insights may help infer the behavior of other common embedding media: water has comparable vaporization enthalpy (Drisdell et al., 2010[Drisdell, W. S., Saykally, R. J. & Cohen, R. C. (2010). J. Phys. Chem. C, 114, 11880-11885.]) to EtOH, but that value for formaldehyde (active ingredient in formalin) is significantly lower because it exists as a gas at room temperature and ambient pressure. Therefore, we expect that bubble formation to be more significant in formalin than EtOH or water under similar experimental conditions. Besides, the sizes of the sample and container may also be modified, albeit not necessarily easily, to reduce the radiation dose applied to the sample and thereby the tendency of bubble formation. Finally, we want to note that the temporal quantities such as tbo, tbbo and tabo that are empirically determined here are contingent on the bubble size exceeding the resolution of the imaging system. At higher resolution, smaller bubbles may be observed, so their values may differ. However, the power-law growth characteristics of the bubbles indicate that the true tbo differ by only a few seconds, which is a negligible time interval in our analysis of the bubble growth characteristics on the scale of tens of minutes.

4. Conclusion

As we continue to push X-ray imaging to higher resolutions on ever larger samples (Du et al., 2021[Du, M., Di, Z., Gürsoy, D., Xian, R. P., Kozorovitskiy, Y. & Jacobsen, C. (2021). J. Appl. Cryst. 54, 386-401.]; Walsh et al., 2021[Walsh, C. L., Tafforeau, P., Wagner, W. L., Jafree, D. J., Bellier, A., Werlein, C., Kühnel, M. P., Boller, E., Walker-Samuel, S., Robertus, J. L., Long, D. A., Jacob, J., Marussi, S., Brown, E., Holroyd, N., Jonigk, D. D., Ackermann, M. & Lee, P. D. (2021). Nat. Methods, 18, 1532-1541.]), probing the dose limits of bubble formation and developing mitigation methods, either in instrumentation, measurement protocol or data processing, becomes increasingly important. Here, we have combined real-time gas chromatography with in-line X-ray phase-contrast cineradiography to investigate bubble formation under high-energy X-ray irradiation. We observe the quantitative growth characteristics of X-ray-induced bubble formation from the microscopic to the macroscopic level. We have shown how degassing can substantially delay bubble nucleation in the heterogeneous environment and thereby lengthen the duration of uninterrupted imaging.

Our current identification of the stable, long-timescale gas products from X-ray irradiation invites further investigation into the corresponding short-timescale mechanism down to the molecular level, preferably in simplified systems where multiple probes may be simultaneously used. Collectively, they will facilitate model-building for radiation–matter interaction and bubble dynamics in complex media from first principles (Menzl et al., 2016[Menzl, G., Gonzalez, M. A., Geiger, P., Caupin, F., Abascal, J. L. F., Valeriani, C. & Dellago, C. (2016). Proc. Natl Acad. Sci. USA, 113, 13582-13587.]), or using continuum models coupled with local geometry (Dollet et al., 2019[Dollet, B., Marmottant, P. & Garbin, V. (2019). Annu. Rev. Fluid Mech. 51, 331-355.]). Furthermore, the study illustrates the potential of X-rays as simultaneously a probe and an initiator of bubble dynamics; future research should investigate more efficient degassing methods and quantify the dissolved gas concentration in tissue, as well as continue the efforts to reduce the X-ray dose while keeping or even increasing the data quality. The high sensitivity and resolution of modern phase-contrast X-ray imaging offer an appropriate tool for soft materials rheological characterization (Barney et al., 2020[Barney, C. W., Dougan, C. E., McLeod, K. R., Kazemi-Moridani, A., Zheng, Y., Ye, Z., Tiwari, S., Sacligil, I., Riggleman, R. A., Cai, S., Lee, J., Peyton, S. R., Tew, G. N. & Crosby, A. J. (2020). Proc. Natl Acad. Sci. USA, 117, 9157-9165.]; Zimberlin et al., 2010[Zimberlin, J. A., McManus, J. J. & Crosby, A. J. (2010). Soft Matter, 6, 3632.]) using bubbles as the local probe, which may be carried out in opaque media that are traditionally not amenable to study with optical imaging means. In these contexts, our results motivate the continued development of high-speed and multiscale tomography (Finegan et al., 2015[Finegan, D. P., Scheel, M., Robinson, J. B., Tjaden, B., Hunt, I., Mason, T. J., Millichamp, J., Di Michiel, M., Offer, G. J., Hinds, G., Brett, D. J. L. & Shearing, P. R. (2015). Nat. Commun. 6, 6924.]) and experimental designs to sample ensembles of diverse bubbles in 3D (Jung et al., 2015[Jung, J. W., Jeon, H. M., Pyo, J., Lim, J., Weon, B. M., Kohmura, Y., Ishikawa, T. & Je, J. H. (2015). Sci. Rep. 4, 5083.]) with a large field of view. When combined with energy-dependent studies and in situ thermometry (Alaulamie et al., 2017[Alaulamie, A. A., Baral, S., Johnson, S. C. & Richardson, H. H. (2017). Small, 13, 1601989.]), our approach will uncover the progression and characteristics of radiation–matter interaction on the intermediate spatiotemporal scale.

5. Data availability

The complete data generated and analyzed in the current study are publicly available in the Zenodo repository at https://doi.org/10.5281/zenodo.7760251 (Xian et al., 2023[Xian, R. P., Brunet, J., Huang, Y., Wagner, W. L., Lee, P. D., Tafforeau, P. & Walsh, C. L. (2023). A closer look at high-energy X-ray-induced bubble formation during soft tissue imaging, https://doi.org/10.5281/zenodo.7760251.]). This repository contains the following underlying data: (i) X-ray_imaging.zip (source files and processed files for bubble cumulative quantification and bubble growth quantification). (ii) Gaz_chromatography.zip (source files). (iii) Analysis.zip (code and result tables used for this paper).

6. Related literature

The following references, not cited in the main body of the paper, have been cited in the supporting information: Araki (1956[Araki, C. (1956). Bull. Chem. Soc. Jpn, 29, 543-544.]); Aymard et al. (2001[Aymard, P., Martin, D. R., Plucknett, K., Foster, T. J., Clark, A. H. & Norton, I. T. (2001). Biopolymers, 59, 131-144.]); Chen et al. (2012[Chen, R.-C., Dreossi, D., Mancini, L., Menk, R., Rigon, L., Xiao, T.-Q. & Longo, R. (2012). J. Synchrotron Rad. 19, 836-845.]); Clough et al. (1996[Clough, R. L., Gillen, K. T., Malone, G. M. & Wallace, J. S. (1996). Radiat. Phys. Chem. 48, 583-594.]); Ehn et al. (2017[Ehn, S., Sellerer, T., Mechlem, K., Fehringer, A., Epple, M., Herzen, J., Pfeiffer, F. & Noël, P. B. (2017). Phys. Med. Biol. 62, N1-N17.]); Jailin et al. (2017[Jailin, C., Buffière, J.-Y., Hild, F., Poncelet, M. & Roux, S. (2017). J. Synchrotron Rad. 24, 220-231.]); Peng et al. (2017[Peng, T., Thorn, K., Schroeder, T., Wang, L., Theis, F. J., Marr, C. & Navab, N. (2017). Nat. Commun. 8, 14836.]); Regmi & Agah (2018[Regmi, B. P. & Agah, M. (2018). Anal. Chem. 90, 13133-13150.]); Seibert et al. (2015[Seibert, J. A., Boone, J. M. & Lindfors, K. K. (1998). Proc. SPIE, 3336, 348-354.]); Van Nieuwenhove et al. (2015[Van Nieuwenhove, V., De Beenhouwer, J., De Carlo, F., Mancini, L., Marone, F. & Sijbers, J. (2015). Opt. Express, 23, 27975.]); Weitkamp et al. (2013[Weitkamp, T., Haas, D., Wegrzynek, D. & Rack, A. (2013). J. Synchrotron Rad. 20, 205-205.]).

Supporting information


Footnotes

These authors contributed equally to the work.

Acknowledgements

We thank P. Masson and A. Bellier at LADAF in Grenoble, France, for collecting organs from the human donors. We thank Philippe Sabot and Régis Barattin from APIX Analytics (Grenoble, France) for their help with the gas chromatography. We thank the scientists sharing their knowledge and past experiences on the bubbling phenomena they encountered during synchrotron beam times. These people include A. Mittone at ALBA Synchrotron (Barcelona, Spain), P. P. Paul, M. di Michiel and M. Krisch at ESRF, B. Bay at Oregon State University (Corvallis, OR, USA), C. Disney at University College London. RPX thanks R. Santra at the Center for Free-Electron Laser Science (Hamburg, Germany) and S. Carbajo at SLAC National Accelerator Laboratory (Palo Alto, CA, USA) for helpful discussions. In addition, we thank S. E. Verleden at the Antwerp Surgical Training, Anatomy and Research Center (ASTARC) in Belgium for helpful discussion. We thank H. Müller and P. Lloria at ESRF for lending of equipment.

Funding information

This project has been made possible in part by grant number CZIF2021-006424 from the Chan Zuckerberg Initiative Foundation, grant 2020-225394 and 2022-316777 from the Chan Zuckerberg Initiative DAF, an advised fund of Silicon Valley Community Foundation, The ESRF - funding proposal md1252, and the Royal Academy of Engineering (CiET1819/10 to PDL) and the MRC (MR/R025673/1).

References

First citationAlaulamie, A. A., Baral, S., Johnson, S. C. & Richardson, H. H. (2017). Small, 13, 1601989.  CrossRef Google Scholar
First citationAraki, C. (1956). Bull. Chem. Soc. Jpn, 29, 543–544.  CrossRef CAS Web of Science Google Scholar
First citationAymard, P., Martin, D. R., Plucknett, K., Foster, T. J., Clark, A. H. & Norton, I. T. (2001). Biopolymers, 59, 131–144.  CrossRef PubMed CAS Google Scholar
First citationBarney, C. W., Dougan, C. E., McLeod, K. R., Kazemi-Moridani, A., Zheng, Y., Ye, Z., Tiwari, S., Sacligil, I., Riggleman, R. A., Cai, S., Lee, J., Peyton, S. R., Tew, G. N. & Crosby, A. J. (2020). Proc. Natl Acad. Sci. USA, 117, 9157–9165.  CrossRef CAS PubMed Google Scholar
First citationBeyerlein, K. R., Jönsson, H. O., Alonso-Mori, R., Aquila, A., Bajt, S., Barty, A., Bean, R., Koglin, J. E., Messerschmidt, M., Ragazzon, D., Sokaras, D., Williams, G. J., Hau-Riege, S., Boutet, S., Chapman, H. N., Tîmneanu, N. & Caleman, C. (2018). Proc. Natl Acad. Sci. USA, 115, 5652–5657.  Web of Science CrossRef CAS PubMed Google Scholar
First citationBranger, A. B. & Eckmann, D. M. (1999). J. Appl. Phys. 87, 1287–1295.  CAS Google Scholar
First citationBras, W., Myles, D. A. A. & Felici, R. (2021). J. Phys. Condens. Matter, 33, 423002.  Web of Science CrossRef Google Scholar
First citationBravin, A., Coan, P. & Suortti, P. (2013). Phys. Med. Biol. 58, R1–R35.  Web of Science CrossRef PubMed Google Scholar
First citationBrennen, C. E. (2013). Cavitation Bubble Dynamics. Cambridge University Press.  Google Scholar
First citationBrunet, J., Walsh, C. L., Wagner, W. L., Bellier, A., Werlein, C., Marussi, S., Jonigk, D. D., Verleden, S. E., Ackermann, M., Lee, P. D. & Tafforeau, P. (2023). Nat. Protoc. 18, 1441–1461.  CrossRef CAS PubMed Google Scholar
First citationBusse, M., Müller, M., Kimm, M. A., Ferstl, S., Allner, S., Achterhold, K., Herzen, J. & Pfeiffer, F. (2018). Proc. Natl Acad. Sci. USA, 115, 2293–2298.  Web of Science CrossRef CAS PubMed Google Scholar
First citationCharalambous, H., Abraham, D. P., Dunlop, A. R., Trask, S. E., Jansen, A. N., Tanim, T. R., Chinnam, P. R., Colclasure, A. M., Xu, W., Yakovenko, A. A., Borkiewicz, O. J., Gallington, L. C., Ruett, U., Wiaderek, K. M. & Ren, Y. (2021). J. Power Sources, 507, 230253.  CrossRef Google Scholar
First citationChen, R.-C., Dreossi, D., Mancini, L., Menk, R., Rigon, L., Xiao, T.-Q. & Longo, R. (2012). J. Synchrotron Rad. 19, 836–845.  Web of Science CrossRef IUCr Journals Google Scholar
First citationClough, R. L., Gillen, K. T., Malone, G. M. & Wallace, J. S. (1996). Radiat. Phys. Chem. 48, 583–594.  CrossRef CAS Google Scholar
First citationDisney, C. M., Mo, J., Eckersley, A., Bodey, A. J., Hoyland, J. A., Sherratt, M. J., Pitsillides, A. A., Lee, P. D. & Bay, B. K. (2022). Acta Biomater. 138, 361–374.  CrossRef CAS PubMed Google Scholar
First citationDollet, B., Marmottant, P. & Garbin, V. (2019). Annu. Rev. Fluid Mech. 51, 331–355.  CrossRef Google Scholar
First citationDrisdell, W. S., Saykally, R. J. & Cohen, R. C. (2010). J. Phys. Chem. C, 114, 11880–11885.  CrossRef CAS Google Scholar
First citationDu, M., Di, Z., Gürsoy, D., Xian, R. P., Kozorovitskiy, Y. & Jacobsen, C. (2021). J. Appl. Cryst. 54, 386–401.  Web of Science CrossRef CAS IUCr Journals Google Scholar
First citationEhn, S., Sellerer, T., Mechlem, K., Fehringer, A., Epple, M., Herzen, J., Pfeiffer, F. & Noël, P. B. (2017). Phys. Med. Biol. 62, N1–N17.  CrossRef CAS PubMed Google Scholar
First citationErrico, F. d' (2001). Nucl. Instrum. Methods Phys. Res. B, 184, 229–254.  Google Scholar
First citationFinegan, D. P., Scheel, M., Robinson, J. B., Tjaden, B., Hunt, I., Mason, T. J., Millichamp, J., Di Michiel, M., Offer, G. J., Hinds, G., Brett, D. J. L. & Shearing, P. R. (2015). Nat. Commun. 6, 6924.  Web of Science CrossRef PubMed Google Scholar
First citationFreeman, G. R. (1974). Radiation Chemistry of Ethanol: A Review of Data on Yields, Reaction Rate Parameters, and Spectral Properties of Transients. National Institute of Standards and Technology, Gaithersburg, MD, USA.  Google Scholar
First citationHaefeli-Bleuer, B. & Weibel, E. R. (1988). Anat. Rec. 220, 401–414.  CAS PubMed Google Scholar
First citationHasan, F., Al Mahmud, K. A. H., Khan, M. I., Patil, S., Dennis, B. H. & Adnan, A. (2021). Multiscale Sci. Eng. 3, 67–87.  CrossRef Google Scholar
First citationHémonnot, C. Y. J. & Köster, S. (2017). ACS Nano, 11, 8542–8559.  Web of Science PubMed Google Scholar
First citationHonkimäki, V., Tafforeau, P. & Wright, J. (2020). Synchrotron Radiat. News, 33(6), 5–10.  Google Scholar
First citationHowells, M. R., Beetz, T., Chapman, H. N., Cui, C., Holton, J. M., Jacobsen, C. J., Kirz, J., Lima, E., Marchesini, S., Miao, H., Sayre, D., Shapiro, D. A., Spence, J. C. H. & Starodub, D. (2009). J. Electron Spectrosc. Relat. Phenom. 170, 4–12.  Web of Science CrossRef CAS Google Scholar
First citationHubbell, J. H. (1999). Phys. Med. Biol. 44, R1–R22.  Web of Science CrossRef PubMed CAS Google Scholar
First citationJacobsen, C. (2020). X-ray Microscopy, pp. 457–495. Cambridge University Press.  Google Scholar
First citationJailin, C., Buffière, J.-Y., Hild, F., Poncelet, M. & Roux, S. (2017). J. Synchrotron Rad. 24, 220–231.  Web of Science CrossRef IUCr Journals Google Scholar
First citationJones, S. F., Evans, G. M. & Galvin, K. P. (1999). Adv. Colloid Interface Sci. 80, 27–50.  CrossRef CAS Google Scholar
First citationJung, J. W., Jeon, H. M., Pyo, J., Lim, J., Weon, B. M., Kohmura, Y., Ishikawa, T. & Je, J. H. (2015). Sci. Rep. 4, 5083.  CrossRef Google Scholar
First citationKitchen, M. J., Buckley, G. A., Gureyev, T. E., Wallace, M. J., Andres-Thio, N., Uesugi, K., Yagi, N. & Hooper, S. B. (2017). Sci. Rep. 7, 15953.  Web of Science CrossRef PubMed Google Scholar
First citationLång, K., Arboleda, C., Forte, S., Wang, Z., Prevrhal, S., Koehler, T., Kuhn, N., David, B., Jefimovs, K., Kubik-Huch, R. A. & Stampanoni, M. (2019). Eur. Radiol. Exp. 3, 19.  PubMed Google Scholar
First citationLe Caër, S. (2011). Water, 3, 235–253.  Google Scholar
First citationLee, J. S., Weon, B. M. & Je, J. H. (2013). J. Phys. D Appl. Phys. 46, 494006.  CrossRef Google Scholar
First citationLeong, A. F. T., Buckley, G. A., Paganin, D. M., Hooper, S. B., Wallace, M. J. & Kitchen, M. J. (2014). Biomed. Opt. Expr. 5, 4024.  CrossRef Google Scholar
First citationLussac, E., Barattin, R., Cardinael, P. & Agasse, V. (2016). Crit. Rev. Anal. Chem. 46, 455–468.  CrossRef CAS PubMed Google Scholar
First citationMao, W. L., Mao, H., Meng, Y., Eng, P. J., Hu, M. Y., Chow, P., Cai, Y. Q., Shu, J. & Hemley, R. J. (2006). Science, 314, 636–638.  Web of Science CrossRef PubMed CAS Google Scholar
First citationMeents, A., Gutmann, S., Wagner, A. & Schulze-Briese, C. (2010). Proc. Natl Acad. Sci. USA, 107, 1094–1099.  Web of Science CrossRef CAS PubMed Google Scholar
First citationMenzl, G., Gonzalez, M. A., Geiger, P., Caupin, F., Abascal, J. L. F., Valeriani, C. & Dellago, C. (2016). Proc. Natl Acad. Sci. USA, 113, 13582–13587.  CrossRef CAS PubMed Google Scholar
First citationMesu, J. G., Beale, A. M., de Groot, F. M. F. & Weckhuysen, B. M. (2006). J. Phys. Chem. B, 110, 17671–17677.  Web of Science CrossRef PubMed CAS Google Scholar
First citationMittone, A., Fardin, L., Di Lillo, F., Fratini, M., Requardt, H., Mauro, A., Homs-Regojo, R. A., Douissard, P.-A., Barbone, G. E., Stroebel, J., Romano, M., Massimi, L., Begani-Provinciali, G., Palermo, F., Bayat, S., Cedola, A., Coan, P. & Bravin, A. (2020). J. Synchrotron Rad. 27, 1347–1357.  Web of Science CrossRef CAS IUCr Journals Google Scholar
First citationMoosmann, J., Ershov, A., Altapova, V., Baumbach, T., Prasad, M. S., LaBonne, C., Xiao, X., Kashef, J. & Hofmann, R. (2013). Nature, 497, 374–377.  CrossRef CAS PubMed Google Scholar
First citationMuth, C. M. & Shank, E. S. (2000). N. Engl. J. Med. 342, 476–482.  CrossRef PubMed CAS Google Scholar
First citationPapadopoulou, V., Eckersley, R. J., Balestra, C., Karapantsios, T. D. & Tang, M. (2013). Adv. Colloid Interface Sci. 191–192, 22–30.  CrossRef CAS PubMed Google Scholar
First citationPeng, T., Thorn, K., Schroeder, T., Wang, L., Theis, F. J., Marr, C. & Navab, N. (2017). Nat. Commun. 8, 14836.  CrossRef PubMed Google Scholar
First citationProsperetti, A. (2017). Annu. Rev. Fluid Mech. 49, 221–248.  CrossRef Google Scholar
First citationRegmi, B. P. & Agah, M. (2018). Anal. Chem. 90, 13133–13150.  CrossRef CAS PubMed Google Scholar
First citationReichert, H. & Honkimäki, V. (2015). In Synchrotron Light Sources and Free-Electron Lasers, edited by E. Jaeschke, S. Khan, J. Schneider & J. Hastings. Cham: Springer International Publishing.  Google Scholar
First citationRez, P. (2021). Ultramicroscopy, 231, 113301.  CrossRef PubMed Google Scholar
First citationRowden, B. & Garcia-Araez, N. (2020). Energy Rep. 6, 10–18.  CrossRef Google Scholar
First citationRoy, S. C. (2001). Radiat. Phys. Chem. 61, 271–281.  CrossRef CAS Google Scholar
First citationRussi, E. W. (1998). Thorax, 53, S20–S24.  CrossRef PubMed Google Scholar
First citationSaccomano, M., Albers, J., Tromba, G., Dobrivojević Radmilović, M., Gajović, S., Alves, F. & Dullin, C. (2018). J. Synchrotron Rad. 25, 1153–1161.  Web of Science CrossRef CAS IUCr Journals Google Scholar
First citationSanchez-Cano, C., Alvarez-Puebla, R. A., Abendroth, J. M., Beck, T., Blick, R., Cao, Y., Caruso, F., Chakraborty, I., Chapman, H. N., Chen, C., Cohen, B. E., Conceição, A. L. C., Cormode, D. P., Cui, D. et al. (2021). ACS Nano, 15, 3754–3807.  CAS PubMed Google Scholar
First citationSapoval, B., Filoche, M. & Weibel, E. R. (2002). Proc. Natl Acad. Sci. USA, 99, 10411–10416.  CrossRef PubMed CAS Google Scholar
First citationSazonov, A. B., Marchenko, N. V. & Nikitin, A. V. (2015). High Energy Chem. 49, 223–233.  CrossRef CAS Google Scholar
First citationSeibert, J. A., Boone, J. M. & Lindfors, K. K. (1998). Proc. SPIE, 3336, 348–354.  CrossRef Google Scholar
First citationSocha, J. J., Westneat, M. W., Harrison, J. F., Waters, J. S. & Lee, W. (2007). BMC Biol. 5, 6.  Google Scholar
First citationTang, R., Li, Y., Qin, L., Yan, F., Yang, G. & Chen, K. (2021). Med. Phys. 48, 3459–3469.  CrossRef PubMed Google Scholar
First citationTöpperwien, M., van der Meer, F., Stadelmann, C. & Salditt, T. (2018). Proc. Natl Acad. Sci. USA, 115, 6940–6945.  Web of Science PubMed Google Scholar
First citationTsai, W. L., Hsu, P. C., Hwu, Y., Chen, C. H., Chang, L. W., Je, J. H., Lin, H. M., Groso, A. & Margaritondo, G. (2002). Nature, 417, 139.  Web of Science CrossRef PubMed Google Scholar
First citationVan Nieuwenhove, V., De Beenhouwer, J., De Carlo, F., Mancini, L., Marone, F. & Sijbers, J. (2015). Opt. Express, 23, 27975.  Web of Science CrossRef PubMed Google Scholar
First citationWalsh, C. L., Tafforeau, P., Wagner, W. L., Jafree, D. J., Bellier, A., Werlein, C., Kühnel, M. P., Boller, E., Walker-Samuel, S., Robertus, J. L., Long, D. A., Jacob, J., Marussi, S., Brown, E., Holroyd, N., Jonigk, D. D., Ackermann, M. & Lee, P. D. (2021). Nat. Methods, 18, 1532–1541.  Web of Science CrossRef CAS PubMed Google Scholar
First citationWang, Y., Zaytsev, M. E., Lajoinie, G., The, H. L., Eijkel, J. C. T., van den Berg, A., Versluis, M., Weckhuysen, B. M., Zhang, X., Zandvliet, H. J. W. & Lohse, D. (2018). Proc. Natl Acad. Sci. USA, 115, 7676–7681.  CrossRef CAS PubMed Google Scholar
First citationWeathersby, P. K. & Homer, L. D. (1980). Undersea Biomed. Res. 7, 277–296.  CAS PubMed Google Scholar
First citationWeitkamp, T., Haas, D., Wegrzynek, D. & Rack, A. (2013). J. Synchrotron Rad. 20, 205–205.  CrossRef IUCr Journals Google Scholar
First citationWen, H., Gomella, A. A., Patel, A., Lynch, S. K., Morgan, N. Y., Anderson, S. A., Bennett, E. E., Xiao, X., Liu, C. & Wolfe, D. E. (2013). Nat. Commun. 4, 2659.  Web of Science CrossRef PubMed Google Scholar
First citationWeon, B. M., Je, J. H., Hwu, Y. & Margaritondo, G. (2008). Phys. Rev. Lett. 100, 217403.  Web of Science CrossRef PubMed Google Scholar
First citationWeon, B. M., Lee, J. S., Je, J. H. & Fezzaa, K. (2011). Phys. Rev. E, 84, 032601.  Web of Science CrossRef Google Scholar
First citationWilke, J., Krause, F., Niederer, D., Engeroff, T., Nürnberger, F., Vogt, L. & Banzer, W. (2015). J. Anat. 226, 440–446.  CrossRef CAS PubMed Google Scholar
First citationWilkins, S. W., Gureyev, T. E., Gao, D., Pogany, A. & Stevenson, A. W. (1996). Nature, 384, 335–338.  CrossRef CAS Web of Science Google Scholar
First citationWu, X., Liu, H. & Yan, A. (2005). Opt. Lett. 30, 379.  CrossRef PubMed Google Scholar
First citationXian, R. P., Brunet, J., Huang, Y., Wagner, W. L., Lee, P. D., Tafforeau, P. & Walsh, C. L. (2023). A closer look at high-energy X-ray-induced bubble formation during soft tissue imaging, https://doi.org/10.5281/zenodo.7760251Google Scholar
First citationXian, R. P., Walsh, C. L., Verleden, S. E., Wagner, W. L., Bellier, A., Marussi, S., Ackermann, M., Jonigk, D. D., Jacob, J., Lee, P. D. & Tafforeau, P. (2022). Sci. Data, 9, 264.  CrossRef PubMed Google Scholar
First citationZhanmu, O., Yang, X., Gong, H. & Li, X. (2020). Sci. Rep. 10, 12639.  CrossRef PubMed Google Scholar
First citationZimberlin, J. A., McManus, J. J. & Crosby, A. J. (2010). Soft Matter, 6, 3632.  CrossRef Google Scholar

This is an open-access article distributed under the terms of the Creative Commons Attribution (CC-BY) Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited.

Journal logoJOURNAL OF
SYNCHROTRON
RADIATION
ISSN: 1600-5775
Follow J. Synchrotron Rad.
Sign up for e-alerts
Follow J. Synchrotron Rad. on Twitter
Follow us on facebook
Sign up for RSS feeds